Cart summary

You have no items in your shopping cart.

Anti-Musashi 1/Msi1 Antibody (monoclonal, 2B9)

Catalog Number: orb623779

DispatchUsually dispatched within 3-4 weeks
$ 210.00
Catalog Numberorb623779
CategoryAntibodies
DescriptionAnti-Musashi 1/Msi1 Antibody (monoclonal, 2B9). Tested in IF, IHC, ICC, WB applications. This antibody reacts with Human, Mouse, Rat.
Species/HostMouse
ClonalityMonoclonal
Clone Number2B9
Tested applicationsICC, IF, IHC, WB
ReactivityHuman, Mouse, Rat
IsotypeMouse IgG2b
ImmunogenA synthetic peptide corresponding to a sequence at the N-terminus of human Musashi 1/Msi1, identical to the related mouse and rat sequences.
ConcentrationAdding 0.2 ml of distilled water will yield a concentration of 500 μg/ml.
Form/AppearanceLyophilized
ConjugationUnconjugated
MW39 kDa
UniProt IDO43347
StorageMaintain refrigerated at 2-8°C for up to 2 weeks. For long term storage store at -20°C in small aliquots to prevent freeze-thaw cycles.
Alternative namesMsi 1; Msi1; Musashi-1; Musashi1
Read more...
NoteFor research use only
Application notesWestern blot, 0.1-0.5μg/ml, Human, Mouse, Rat Immunohistochemistry (Paraffin-embedded Section), 0.5-1μg/ml, Human, Mouse, Rat Immunocytochemistry/Immunofluorescence, 2μg/ml, Human. Add 0.2ml of distilled water will yield a concentration of 500ug/ml
Expiration Date12 months from date of receipt.
Anti-Musashi 1/Msi1 Antibody (monoclonal, 2B9)

IF analysis of MSI using anti-MSI antibody. MSI was detected in immunocytochemical section of MCF7 cells. Enzyme antigen retrieval was performed using IHC enzyme antigen retrieval reagent for 15 mins. The cells were blocked with 10% goat serum. And then incubated with 2 µg/mL mouse anti-MSI Antibody overnight at 4°C. DyLight®488 Conjugated Goat Anti-Mouse IgG was used as secondary antibody at 1:100 dilution and incubated for 30 minutes at 37°C. The section was counterstained with DAPI. Visualize using a fluorescence microscope and filter sets appropriate for the label used.

Anti-Musashi 1/Msi1 Antibody (monoclonal, 2B9)

IHC analysis of MSI using anti-MSI antibody. MSI was detected in paraffin-embedded section of human lung cancer tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 1g/ml mouse anti-MSI Antibody overnight at 4C. Biotinylated goat anti-mouse IgG was used as secondary antibody and incubated for 30 minutes at 37C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.

Anti-Musashi 1/Msi1 Antibody (monoclonal, 2B9)

IHC analysis of MSI using anti-MSI antibody. MSI was detected in paraffin-embedded section of human rectum cancer tissue. Heat mediated antigen retrieval was performed in EDTA buffer (pH8.0, epitope retrieval solution). The tissue section was blocked with 10% goat serum. The tissue section was then incubated with 1g/ml mouse anti-MSI Antibody overnight at 4C. Biotinylated goat anti-mouse IgG was used as secondary antibody and incubated for 30 minutes at 37C. The tissue section was developed using Strepavidin-Biotin-Complex (SABC) with DAB as the chromogen.

Anti-Musashi 1/Msi1 Antibody (monoclonal, 2B9)

Western blot analysis of MSI using anti-MSI antibody. Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 50 ug of sample under reducing conditions. Lane 1: human A549 tissue lysates, Lane 2: human PC-3 whole cell lysates, After Electrophoresis, proteins were transferred to a Nitrocellulose membrane at 150 mA for 50-90 minutes. Blocked the membrane with 5% Non-fat Milk/ TBS for 1.5 hour at RT. The membrane was incubated with mouse anti-MSI antigen affinity purified polyclonal antibody at 0.5 µg/mL overnight at 4°C, then washed with TBS-0.1% Tween 3 times with 5 minutes each and probed with a goat anti-mouse IgG-HRP secondary antibody at a dilution of 1:10000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit with Tanon 5200 system. A specific band was detected for MSI at approximately 39 KD. The expected band size for MSI is at 39 KD.